Error code
Description
242.20
Took too long to ramp up dc feed motor in tray 2. Go to
242.21
Pick motor stall in tray 2.
242.22
Tray 2 pick motor underspeed.
242.24
DC Feed ACM stalled on the last pick attempt in
tray 2.
242.32
Tray not ready.
242.33
Pick received but detected a tray pulled.
242.41
Motor 1 (Pick/Lift) Elevator motor stalled.
242.42
Motor 1 (Pick/Lift) Elevator motor PWM overflow
error (underspeed). Motor underspeed (max PWM
and motor underspeed, typical accordion jam).
242.43
Motor 1 (Pick/Lift) motor ramp (end ramp - did not
reach speed, typical pack feed paper jam).
242.44
Motor 2 (Separator/Pass through) motor stalled.
242.45
Motor 2 (Separator/Pass through) motor PWM
overflow error (underspeed). Motor underspeed
(max PWM and motor underspeed, typical
accordion jam).
242.46
Motor 2 (Separator/Pass through) motor ramp
(end ramp - did not reach speed, typical pack feed
paper jam).
242.47
Motor 3 motor stalled.
242.48
Motor 3 motor PWM overflow error (underspeed).
Motor underspeed (max PWM and motor
underspeed, typical accordion jam).
242.49
Motor 3 motor ramp (end ramp - did not reach
speed, typical pack feed paper jam).
Action
page
Diagnostic information
87
"Option tray jam service check" on
92.
7016