6.6.4

Using the Oxygen Supply Adapter

WARNING!
Read the section 2.9 Oxygen Usage — Warning and Precautions, page 19 before using the
Vivo 3 with oxygen.
Supplemental oxygen with a flow up to 30 l/min can be added by an oxygen source with
rotameter such as oxygen cylinder, central oxygen supply system or an oxygen concentrator.
Supplemental Oxygen Supply Requirements
Property
Maximum flow
Maximum pressure
Supply source
Connector
Connect the Oxygen supply
1
Connect the oxygen adapter (article no. 005032) to the oxygen supply's tube.
2 Connect the oxygen adapter to the oxygen port at the back of the Vivo 3. See 3.3
Ventilator Back , page 23 for detailed information.
3 If using a device for monitoring the oxygen saturation, connect it according to the
supplier instructions.
CAUTION!
Do not add Oxygen before therapy has been started.
6.6.5

Using the Nurse Call Connection

The Vivo 3 can be connected to a nurse call system through a port on the accessory box.
When connected, alarms from the Vivo 3 will be forwarded to the nurse call system.
1
Connect the Accessory box to the Communication port at the back of the Vivo 3.
2 Connect the nurse call cable to the Nurse call/
Remote alarm port on the accessory box.
⇒The Nurse call symbol is now lit on the display.
3 Trigger an alarm on the Vivo 3 and check that it
activates the nurse call system. For detailed
information about triggering alarms, see .
48 How to Use the Vivo 3
User Manual
Requirement
30 l/min.
100 kPa
Source equipped with rotameter. Examples of supply sources:
Oxygen cylinder
Central oxygen supply
Oxygen concentrator
The oxygen source shall be equipped with the Breas Low Pressure
Oxygen Adapter, art. no. 005032
Doc. 007231 F-3