Vista Link Tm Traps; Table 10: Vistalink™ Controlled Parameters - evertz 7700 Manual

Hd format up/down/cross converter
Hide thumbs Also See for 7700:
Table of Contents

Advertisement

Video level
Hue
H blanking
VBI processing
Y Filter Selection
Wideband Frequency.
Chroma Filter
Load Preset
Store Preset
Auto Recall Presets
GPI 1
GPI 2
GPI 3
GPI 4
GPI4 function
TM
8.4.
VISTALINK
The 7710XUC-HD modules will raise a VistaLINK™ trap if the temperature of the main or sub cards rises
above 100 °F.
Controls the output video level
Controls the output video hue
Controls the width of horizontal blanking
Either pass or blank the vertical blanking interval lines
Standard composite filtering or adjustable filtering is selectable
Controls the frequency response with the wideband filter selected
Various chroma bandwidths are available with this control
Used to recall the current module configuration
Used to store the current module configuration
Enables automatic preset recall when input or output changes
Selects the function of GPIO1
Selects the function of GPIO2
Selects the function of GPIO3
Selects the function of GPIO4
Determines whether GPI4 is used as a GPI or the 6Hz source
Table 10: VistaLINK™ Controlled Parameters
TRAPS
7710XUC-HD HD Format Up/Down/Cross Converter
Revision 1.0
7700 MultiFrame Manual
7710XUC-HD
-59