evertz 7700 Manual

Sd/hd re-clocking electrical to fiber converter
Hide thumbs Also See for 7700:

Advertisement

Quick Links

1.
OVERVIEW.......................................................................................................................................... 1
2.
INSTALLATION................................................................................................................................... 3
2.1. SERIAL DIGITAL COAXIAL CONNECTIONS ........................................................................... 3
2.2. OPTICAL CONNECTIONS ......................................................................................................... 4
2.3. CARE AND HANDLING OF OPTICAL FIBER............................................................................ 4
2.3.1. Safety .............................................................................................................................. 4
2.3.2. Assembly......................................................................................................................... 4
2.3.3. Labeling........................................................................................................................... 5
2.3.4. Handling and Connecting Fibers ..................................................................................... 5
3.
SPECIFICATIONS............................................................................................................................... 6
3.1. SERIAL VIDEO INPUT ............................................................................................................... 6
3.2. SERIAL VIDEO OUTPUTS ......................................................................................................... 6
3.3. OPTICAL OUTPUT..................................................................................................................... 6
3.4. ELECTRICAL ............................................................................................................................. 7
3.5. COMPLIANCE ............................................................................................................................ 7
3.6. PHYSICAL .................................................................................................................................. 7
4.
STATUS INDICATORS AND DISPLAYS ........................................................................................... 8
4.1. STATUS INDICATOR LEDS....................................................................................................... 8
4.2. DOT-MATRIX DISPLAY ............................................................................................................. 9
4.2.1. Displaying The Equalization Strength ............................................................................. 9
4.2.2. Displaying the EDH Errors .............................................................................................. 9
4.2.3. Displaying the Video Standard ...................................................................................... 10
5.
JUMPERS AND LOCAL CONTROLS .............................................................................................. 11
5.1. SELECTING THE RECLOCKING MODE ................................................................................. 11
5.2. SELECTING THE RECLOCKING RATE .................................................................................. 11
BY THE GLOBAL FRAME STATUS ........................................................................................ 11
7707EO-HD SD/HD Re-Clocking Electrical to Fiber Converter

TABLE OF CONTENTS

Revision 1.5
7700 Multi-Frame Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 7700 and is the answer not in the manual?

Questions and answers

Summary of Contents for evertz 7700

  • Page 1: Table Of Contents

    7700 Multi-Frame Manual 7707EO-HD SD/HD Re-Clocking Electrical to Fiber Converter TABLE OF CONTENTS OVERVIEW............................1 INSTALLATION........................... 3 2.1. SERIAL DIGITAL COAXIAL CONNECTIONS ................3 2.2. OPTICAL CONNECTIONS ......................4 2.3. CARE AND HANDLING OF OPTICAL FIBER................4 2.3.1. Safety ..........................4 2.3.2.
  • Page 2 7700 Multi-Frame Manual 7707EO-HD SD/HD Re-Clocking Electrical to Fiber Converter 5.4. SELECTING WHETHER THE MODULE WILL BE CONTROLLED FROM THE LOCAL CONTROLS OR THROUGH THE V LINK INTERFACE ........12 ISTA ® 5.5. CONFIGURING THE MODULE FOR FIRMWARE UPGRADES ..........12 VISTALINK REMOTE MONITORING/CONTROL ................
  • Page 3 Nov 08 Information contained in this manual is believed to be accurate and reliable. However, Evertz assumes no responsibility for the use thereof nor for the rights of third parties, which may be effected in any way by the use thereof. Any representations in this document concerning performance of Evertz products are for informational use only and are not warranties of future performance, either express or implied.
  • Page 4 7700 Multi-Frame Manual 7707EO-HD SD/HD Re-Clocking Electrical to Fiber Converter WARNING Never look directly into an optical fiber. Non-reversible damage to the eye can occur in a matter of milliseconds. Do not hook up the 7707EO-HD DWDM cards directly with a short fiber optic cable.
  • Page 5: Overview

    7700 Multi-Frame Manual 7707EO-HD SD/HD Re-Clocking Electrical to Fiber Converter OVERVIEW The 7707EO-HD is a VistaLINK enabled, electrical to optical converter for SMPTE 292M (1.485Gb/s), ® SMPTE 259M (143-360Mb/s), SMPTE 344M (540Mb/s), DVB-ASI (270Mb/s) and SMPTE 310M (19.4Mb/s) signals. Monitoring and control of card status and parameters is provided locally at the card edge, and remotely via VistaLINK capability.
  • Page 6: Figure 1-1: 7707Eo-Hd Block Diagram

    7700 Multi-Frame Manual 7707EO-HD SD/HD Re-Clocking Electrical to Fiber Converter Features: • Supports all SMPTE 292M standards at 1.485Gb/s • Supports all SMPTE 259M standards with operation from 143Mb/s-360Mb/s • Supports SMPTE 310M (19.4Mb/s), M2S or DVB-ASI (270Mb/s), SMPTE 344M (540Mb/s), and SMPTE 305M (SDTi) rates •...
  • Page 7: Installation

    7700 Multi-Frame Manual 7707EO-HD SD/HD Re-Clocking Electrical to Fiber Converter INSTALLATION The 7707EO-HD comes with a companion rear plate that has three BNC connectors and one SC/PC (shown), ST/PC or FC/PC optical connector. For information on mounting the rear plate and inserting the module into the frame see section 3 of the 7700FR chapter.
  • Page 8: Optical Connections

    CLASS 1 LASER PRODUCT Background colour: yellow Triangular band: black Symbol: black 2.3.2. Assembly Assembly or repair of the laser sub-module is done only at the Evertz facility and performed only by qualified Evertz technical personnel. 7707EO-HD - 4 Revision 1.5...
  • Page 9: Labeling

    5 cm to avoid fiber-bending loss that will decrease the maximum attainable distance of the fiber cable. The Evertz fiber optic modules come with cable lockout devices, to prevent the user from damaging the fiber by installing a module into a slot in the frame that does not have a suitable I/O module.
  • Page 10: Specifications

    7700 Multi-Frame Manual 7707EO-HD SD/HD Re-Clocking Electrical to Fiber Converter SPECIFICATIONS 3.1. SERIAL VIDEO INPUT Standards: Reclocked: SMPTE 292M, SMPTE 259M A, B, C, D, SMPTE 344M, SMPTE 305M, DVB-ASI, M2S, SMPTE 310M Non-Reclocked: Any bi-level signal type at rates of 19.4 – 1.485Gb/s...
  • Page 11: Electrical

    Class 1 laser product Complies with 24 CFR 1040.10 and 1040.11 IEC 60825-1 EMI/RFI: Complies with FCC Part 15, Class A EU EMC directive 3.6. PHYSICAL 7700 or 7701 frame mounting: Number of slots: 1 7707EO-HD - 7 Revision 1.5...
  • Page 12: Status Indicators And Displays

    7700 Multi-Frame Manual 7707EO-HD SD/HD Re-Clocking Electrical to Fiber Converter STATUS INDICATORS AND DISPLAYS The 7707EO-HD has 9 LED Status indicators and a 4 digit alphanumeric display on the front card edge to show operational status of the card at a glance. The card edge pushbutton is used to select various displays on the alphanumeric display.
  • Page 13: Dot-Matrix Display

    7700 Multi-Frame Manual 7707EO-HD SD/HD Re-Clocking Electrical to Fiber Converter RATE - HD: This Green LED indicates that the reclocker is locked to the 1.485 Gb/s HD rate. EDH DISABLED: This Yellow LED indicates that the user has deactivated error detection on the card edge display for SD signals.
  • Page 14: Displaying The Video Standard

    7700 Multi-Frame Manual 7707EO-HD SD/HD Re-Clocking Electrical to Fiber Converter The EDH error display can only be enabled / disabled when there is a SMPTE 259M or SMPTE 344M input signal. 4.2.3. Displaying the Video Standard When the reclocker is enabled, the 7707EO-HD detects the Video standards of the signal present at its input.
  • Page 15: Jumpers And Local Controls

    7700 Multi-Frame Manual 7707EO-HD SD/HD Re-Clocking Electrical to Fiber Converter JUMPERS AND LOCAL CONTROLS Several jumpers, located at the front of the module, are used to preset various operating modes. Figure 4-1 shows the locations of the jumpers. 5.1. SELECTING THE RECLOCKING MODE The RECLOCK jumper allows the user to set the reclocking mode.
  • Page 16: Selecting Whether The Module Will Be Controlled From The Local Controls Or Through The Vista Link ® Interface

    7700 Multi-Frame Manual 7707EO-HD SD/HD Re-Clocking Electrical to Fiber Converter 5.4. SELECTING WHETHER THE MODULE WILL BE CONTROLLED FROM THE LOCAL CONTROLS OR THROUGH THE VISTALINK INTERFACE ® The MASTER jumper selects whether the module will be controlled from the local user controls or through the VistaLINK interface.
  • Page 17: Vistalink ® Remote Monitoring/Control

    1. An SNMP manager, also known as a Network Management System (NMS), is a computer running special software that communicates with the devices in the network. Evertz VL-Fiber demo Manager graphical user interface (GUI), third party or custom manager software may be used to monitor and control Evertz VistaLINK enabled fiber optic products.
  • Page 18: Controlled Parameters

    7700 Multi-Frame Manual 7707EO-HD SD/HD Re-Clocking Electrical to Fiber Converter 6.3. VISTALINK CONTROLLED PARAMETERS ® When the MASTER jumper is set to the REMOTE position, the following parameters can be remotely controlled through the VistaLINK interface. When the MASTER jumper is set to the LOCAL position the ®...

This manual is also suitable for:

7707eo-hd

Table of Contents