5.4.
SELECTING WHETHER THE MODULE WILL BE CONTROLLED FROM THE
LOCAL CONTROLS OR THROUGH THE VISTALINK
The MASTER jumper selects whether the module will be controlled from the local user controls or through
the VistaLINK
interface.
®
MASTER:
When this jumper is installed in the LOCAL position, the card functions are controlled
through the local jumpers.
When this jumper is installed in the REMOTE position, the card functions are
controlled through the VistaLINK
VistaLINK
controls are not currently active.
5.5.

CONFIGURING THE MODULE FOR FIRMWARE UPGRADES

UPGRADE:
The UPGRADE jumper is used when firmware upgrades are being done to the
module. For normal operation it should be installed in the RUN position (see NOTE
1). See the Upgrading Firmware section of this manual for more information.
To upgrade the firmware in the module unit pull it out of the frame.
UPGRADE jumper into the UPGRADE position (see NOTE 1). Install the Upgrade
cable provided (located in the vinyl pouch in the front of this manual) onto the SERIAL
header at the card edge. Re-install the module into the frame. Run the upgrade as
described in the Upgrading Firmware section of this manual. Once the upgrade is
complete, remove the module from the frame, move the UPGRADE jumper into the
RUN position, remove the upgrade cable and re-install the module. The module is
now ready for normal operation.
NOTE 1:
The Rev (A) boards have incorrect labeling for the RUN / UPGRADE modes. The
jumper labels shown in Figure 4-1 are correct. On Rev (A) boards, for normal RUN
operation set the jumper to the UPGRADE position (as shown on the board label -
away from the front of the module). For UPGRADE operation the jumper must be set
to the RUN position (as shown on the board label - closest to the front of the board).
7707EO-HD - 12
control in enabled. This LED is intended to alert the user that local
®
Revision 1.5
INTERFACE
®
interface. The adjacent yellow LED will be On when
®
Move the

Advertisement