Quick Select Status Indicators; Function Status Indicators; Electronics Unit Status Indicators - evertz 9625LG Instruction Manual

Logo inserters, media keyers
Table of Contents

Advertisement

OUT
This LED indicates that the media item displayed on the front panel is faded out and not
available on the Program output buss. The media item name will not be flashing.
ALL OUT This LED indicates that all media items are faded out from the Program output buss.
LOGO, KEYER
This LED (labelled LOGO on Logo Inserters and KEYER on Media Keyers)
indicates that at least one media item is faded in and available on the Program output buss.
3.1.5.2.

Quick Select Status Indicators

QUICK SELECT
These LEDs indicate that the corresponding Quick Select is active, and the
media item associated with it is faded in.
SHIFT LOCK This LED indicates that the Shift Lock is active and the higher numbered Quick Selects
are being referenced by the QUICK SELECT LEDs and buttons.
3.1.5.3.

Function Status Indicators

PANEL LOCK
This LED indicates that the Panel Lock function is active and the remainder of
the front panel buttons are disabled.
VOICE OVER
This LED (only available on Media Keyer units) indicates that the audio mix
function of the media Keyer is enabled when it is On.
BYPASS This LED indicates that the unit is in Bypass mode when it is On. When it is Off it indicates
that the unit is in normal operating mode.
COMM
This LED is used to signal two types of communication to the 9625LG Series Keyer. When
it is flashing On approximately every 1.5 seconds, that indicates that the control panel is
communicating with the main microprocessor in the unit. When the 9625LG Series Keyer is
under automation control, or logos or other media files are being transferred to or from the
unit using the Nomad™ or Overture™ software, the LED will be on when the unit is
receiving data from the control source.
If it is Off continuously that means that the control panel has lost communications with the
main unit. In that case check the cabling if you are using a remote control panel. Otherwise
the unit may require a reboot if the control buttons on the control panel are not responding.

3.1.6. Electronics Unit Status Indicators

PSU STATUS 1, 2
These green LEDs indicate that the corresponding power supply is functioning
normally. On units fitted with a single power supply the PSU STATUS 2 LED will be Off all
the time. These LEDs are the only ones present on the electronic units of the remote
control versions.