11.2.9.
MENU SCREEN
It is accessed by pressing the icon
The menu screen gives access to:
Power management: the user will have access to this menu as long
as your Smartphone is connected to the same WIFI network as the
4HEAT module.This menu allows to change the power of heating and/
or combustion.
Thermostat management: the values of the main thermostat can be
modified.
12 ALARMS
In case of an anomaly during the operation, the electronics of the stove
intervenes and highlights the irregularities that have ocurred in the different
working phases, depending on the type of fault.
Each very alarm situation blocks the stove automatically. By pressing the key
we unblock the stove. To do this, in the display we must read the word
"Off". Otherwise, you will not able to unlock it. Once the stove has reached
the appropriate cooling temperature, the user can reignite it.
The following table shows the list of alarm codes as well as a description:
ALARM
Er01
Intervention of the safety thermostat, even when the stove is turned off
Er02
Intervention of the safety air pressure switch, only when the stove is turned on.
Er03
Switching off of the stove due to smoke temperature decrease. Possible lack/obstruction of fuel.
Er05
Switching off of the stove due to overheating of the smoke temperature
Er07
Error Encoder: the encoder of the smoke extractor does not receive signal
Er08
Error Encoder: the adjustment of the smoke extractor speed is not possible
Er12
Ignition of the stove unsuccessful
Er15
Power dip - Current interruption.
Er17
The hot air tangential fan does not regulate
Er39
Flow sensor broken
Er41
The primary air flow is not enough during the check-up of the stove
Er42
The primary air flow is high
Values DATE/TIME are not exact after a long power failure
Besides the failure codes, the stove can show the following messages that do not block its operation:
MESSAGE
State of the temperature probes This message appears during the Check Up phase and indicates that the
Sond
temperature detected by one or more probes is equal to the minimum value (0ºC) or the maximum value (depends
on the probe) Check that the probes are open (0°C) or in short-circuit (detect the maximum value of temperature).
Hi
The room temperature is higher than 50°C.
This message means that the operating hours have been reached (1200. It is necessary to call the technical
CLr
assistance service.
This message appears when the system has not been turned off manually during the Ignition phase (after the
OFF dEL
preload): the system will turn off when it works at full capacity.
PCLr
Regular cleaning or burner