Download Print this page

Bronpi Trebol Installation, Operating And Servicing Instruction page 35

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 26
KEY
P1
Views / Menu exit
P2
Modification thermostat (+) / Increase data
P3
Modify combustion power / Save data
P4
Modify thermostat (-) / Decrease data
The following table shows the meaning of the different leds of the display of the stove. The lighting of the leds indicates the activation of the
corresponding device according to the following list:
LED
L1
L2
L3
L4
L6
L5
L7
10.3.
USER MENU 1
10.3.1.
STOVE STATE
When the stove is switched on, by pressing key P1 of the display, it is possible to access the following options that give us some technical
information of the stove. The lower display shows the information (tA, tF, FL, UF, etc) and the upper display shows the value (ºC, rpm, sec,
etc.).
INFORMATION
P1
13 00
5 20
P3
D10.3
the stove, it runs out of fuel, in order to avoid any problem during the next ignition,
it is possible to carry out a preload of pellet of the auger during a maximum time of
300 seconds when the stove is switched off and cold and the door is closed. A long
press of key P3 starts the preload. The lower display will show the message "LoAd",
and the upper display will show the seconds elapsed. In order to interrupt the load,
press any key.
Before proceeding with a new ignition of the stove, do not forget to empty the burner
in order to avoid a dangerous situation (see drawing D10.4).
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
SHORT
S
G
W
tA
Room temperature of the base (ºC)
tF
Smoke temperature (ºC)
FL
Flow speed of the primary air (cm/sec)
UF
Smoke extractor speed (rpm)
Co
Auger activation time (sec)
St
Remaining time until maintenance service 1(h)
St2
Remaining time until maintenance service 2 (h)
FC
Code and firmware version.
10.3.2.
P2
Press key P3 and the display D2 will start flashing. By pressing the key P3, it is
possible to modify the power of the stove according to the values available: power
1, 2, 3, 4, 5 or A (A= automatic combustion). After 5 seconds, the new value will be
saved and the display will return to the normal state (see drawing D10.3).
NOTE. If you activate Soft mode, this regulation won't be available.
10.3.3.
P4
LOAD
If during the operation of
FUNTION
On / Off/ Block reset
Pellet load correction
Pellet manual load
Smoke fan correction
FUNCTION
Led On: heating fan activated
Led On: auger activated
Led On: ignition resistor activated
Led On: thermostat temperature reached
Led On: daily programming
Led On: weekly programming
Led On: weekend programming
VALUE
POWER SET-UP
PELLET MANUAL
P1
34
LONG
30
LOAD
P3
P4
TREBOL - MILA - MINERVA
P2
D10.4