10.3.4.
PELLET LOAD CORRECTION
P1
PELL
P3
10.3.5.
CORRECTION OF THE SMOKE EXTRACTOR SPEED
It is necessary to press for a while key P4 and, later, press again P4 for a while. The
lower display shows the message "UEnt" and the upper display shows the value
introduced. By using keys P2 and P4, it is possible to increase or decrease the value
introduced. The original value introduced is 0 and it goes from -7 ... to ...+7. Note that
each numerical value modified is equal to modify proportionally in all the powers a
5% of the speed value (in rpm) set for the smoke extractor. After 5 seconds, the new
value will be saved and the display will return to the normal state.
P1
13:00
th 22
P3
10.4
USER MENU 2
The following table briefly describes the structure of the user menu 2, which is accessed by simultaneously pressing keys P3 and P4 for 3
seconds.
10.4.1.
MAIN BLOWER POWER REGULATION
NOTE: This option is not available on the Minerva Slim model.
Access is gained by simultaneously pressing P3 and P4 keys for 3 seconds. Then
press the P2 button until the word "Air" appears on the display D1, then confirm the
submenu by pressing the P3 button. Press the P3 key again to enter modification.
The selected value (1, 2, 3, 4, 5 or auto) flashes. Change the value with the P2 and P4
keys. Press the P3 key to go on to modify the other parameters and press P3 again
to store the set value (see drawing D10.8). If you choose speeds 1 to 5, the main fan
speed will always be the one you have chosen (1 minimum speed and 5 maximum
speed), in other words, it will blow the same flow of hot air through the front panel
regardless of the stove operating power, whereas in the auto selection, the fan speed
will be automatically adjusted according to the stove operating power. In the case
you wish deactivate the main blower performance (frontal blower) you shall choose
the option OFF. In work powers 4 and 5, although you have selected OFF mode, the fan will be activated automatically for security reasons
when the stove reaches a temperature fixed by Bronpi Calefacción.
NOTE: If you activate the Soft mode, this regulation won't be available.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
In order to access to the modification mode, it is necessary to press for a while key
P2 and, later, press again P2 for a while. The lower display shows the message "Pell"
P2
and the upper display shows the value introduced. By using keys P2 and P4, it is
possible to increase or decrease the value introduced. The original value introduced
0
is 0 and it goes from -7 ... to ...+7. Note that each numerical value modified is equal
to modify proportionally in all the powers a 2% of the load time value (in seconds) set
for the auger. After 5 seconds, the new value will be saved and the display will return
to the normal state.
Consider that a higher pellet load means a higher thermal power of the stove and,
P4
therefore, a higher fuel consumption. If you observe that the stove is not burning
properly or the mix air/fuel is not appropriate, try to modify the fuel load (see drawing
D10.5
D10.5).
Consider that a higher speed
of the smoke extractor
means a higher capacity to discharge the smoke but also a higher air entry into the
P2
combustion chamber (bigger flame). If you observe that the stove is not burning
properly or the mix air/fuel is not appropriate, try to modify the speed of the smoke
extractor (see drawing D10.6).
10.3.6.
Press key P2 or P4 and the display D4 will start flashing. By pressing keys P2 or P4, it
P4
is possible to select the temperature desired for the room (see drawing D10.7). After
5 seconds, the new value will be saved and the display will return to the normal state.
D10.7
MENU
01 - Air
02 - Can
03 – Cron
04 - oroL
00 - TELE
05 - AuPo
06 - LoAd
07 - SoFt
08 - TPAr
ADJUSTMENT OF THE ROOM TEMPERATURE
SUBMENU
Adjusting the main ducted fan power
Ducted fan power adjustment
Time programming
Set date and time
Radiocontrol (It's useless)
Automatic power
Manual pellet loading
Soft mode (minimum power)
** Only for technical personnel
35
P1
0
UENT
P3
P1
auto
air
P3
TREBOL - MILA - MINERVA
P2
P4
D10.6
P2
P4
D10.8