Powering On The Pwr600 Dc Power Supply - Allied Telesis x950-52XTQm Installation Manual

Standalone switches, advanced layer 3+ alliedware plus
Table of Contents

Advertisement

Chapter 9: Verifying and Configuring the Switch
Powering on the
PWR600 DC
Power Supply
162
Figure 108. Connecting the Power Cord to an AC Power Source
Note
The illustration shows the North American power cord. Your power
cord may be different.
4. If the switch has two AC power supplies, repeat this procedure to
connect a power cord to the second power supply.
5. If you have the PWR600 DC power supply installed on the switch, go
to "Powering on the PWR600 DC Power Supply" on page 162.
6. Wait two minutes for the switch to initialize its management software.
7. Go to "Starting a Local Management Session" on page 164.
To power on the switch with the PWR600 DC Power Supply, perform the
following procedure:
1. Verify that the DC power source unit that provides power to the switch
is powered off. If there are two DC power supplies, verify that both
units are powered off.
2. Verify that the DC power wires are connected to the PWR600 DC
supply.
3. Connect the other end of the power wire to the DC power source unit.
Refer to the documentation included with the unit for instructions.
4. Power on the DC power source unit.