Connecting the unit
6.6 Making the exhaust air connection
NOTICE
NOTICE
6.6.1 Connecting the exhaust air line
Prerequisite The exhaust air line complies with the specifications (see "Unit and
48
When installing the unit under a ventilation system, observe the
regional regulations for air conditioning systems.
Risk of property damage from fouling of the outgoing air ducts
• Not connect the exhaust airline directly to the ventilation system.
Risk of corrosion damage from condensate
• Install the exhaust air line such that condensate cannot collect.
Image: Connecting the exhaust air line
connection data")
1. Connect the exhaust air line to the steam outlet nozzle.
2. Route exhaust air line to the ventilation system with a 3° rise.
3. Fasten the end of the exhaust air line 50 mm (1,97 in) — 200 mm
(7,87 in) underneath the ventilation system.
4. Fill out the Start-up operation report.
Installation instructions