Connecting the unit
INFORMATION
Prerequisite The waste water line complies with the specifications (see "Unit and

6.7 Making the exhaust air connection

NOTICE
NOTICE
38
A
a
b
a
a
c
Image: A Permanent connection without siphon, B Permanent connection with siphon
provided on site
a Wastewater connection
b Waste water line
c Waste water system
Each unit must be connected individually.
Do not join the connection lines.
connection data")
1. Install waste water line up to connection to the waste water
system.
2. Secure waste water line with pipe clamps.
3. Fill the siphon of the unit with drinking water.
4. Fill out the Start-up operation report.
When installing the unit under a ventilation system, observe the
regional regulations for air conditioning systems.
Risk of property damage from fouling of the outgoing air ducts
• Not connect the exhaust airline directly to the ventilation system.
Risk of corrosion damage from condensate
• Install the exhaust air line such that condensate cannot collect.
Installation instructions
B
e
a
d
e
c
a
d
c
b
d Waste water system siphon
e Pipe clamp
f Vacuum breaker