Securing The Unit To Prevent Slipping - Henny Penny FlexFusion FM08-454-G Installation Manual

Electric gold combi
Table of Contents

Advertisement

5.6.2 Securing the unit to prevent slipping

Prerequisite Floor capable of accommodating the weight of the unit
If necessary, the size 2XX combisteamer can be secured to prevent
movement (optional).
c
1
b
Image: Arrangement of the floor plates (view from above)
a Cooking chamber door
b Unit leg or underframe
A special fastening set with floor plates for securing the unit against
sliding is available from the manufacturer as an accessory.
The fastening kit contains two floor plates and all components
required to bolt or bond to the floor.
The unit is fastened by means of two floor plates, as indicated in the
drawing.
Floor without steam barrier
In the case of floors without a steam barrier, the floor plates are
bolted to the floor using the bolts provided.
Floor must be clean and suitable for the manner fastening
Unit set up and aligned in accordance with the planning drawing
1. Align the floor plates in position 1-1 or 2-2 on the unit leg as
shown in the drawing and mark the fastening holes on the floor.
2. Mark the position of all unit legs on the floor.
3. Using suitable lifting equipment, move the unit so that the holes
can be drilled in the floor.
4. Drill holes with a diameter matching that of the anchor sufficiently
deep in the floor.
5. Carefully place the unit in the installation position.
6. Using the anchors and fastening screws provided, screw the floor
plates to the floor.
Installation instructions
2
a
c Floor plates
Installing the unit
2
1
29