Connecting The Drinking Water Connection Line - Henny Penny FlexFusion FM08-454-G Installation Manual

Electric gold combi
Table of Contents

Advertisement

6.4.1 Connecting the drinking water connection line

Prerequisite Water pressure complies with specifications (see "Unit and
a
f
b
e
Image: Water connection
a Softened drinking water
b Backflow preventer
c Softened drinking water
connection
connection data")
Backflow preventer installed
Pressure-resistant connection lines suitable for tap water are
available
1. Connect the connection lines to the drinking water taps using
seals.
2. Flush the connection lines thoroughly.
3. Insert dirt filters into the water connections on the unit.
4. Connect the drinking water connection line to the unit.
5. Connect the connection line for softened drinking water to the unit.
6. Open the tap water valves and check the threaded connectors for
leaks.
7. Fill out the Start-up operation report.
Installation instructions
c
d
d Drinking water connection
e Tap water connection line
f Drinking water
Connecting the unit
43