Prerequisite
d) Install outlet of the sewer line 20 mm (.8 in) above the outlet funnel.
e) Fill water into the discharge funnel.
6.6

Exhaust air connection

When setting up the unit under a fume hood, observe the regional
regulations for air conditioning systems.
CAUTION
Risk of physical damage from fouling of the exhaust air ducts
a) Do not connect the exhaust air line directly to an exhaust air system.
SAFETY INSTRUCTIONS
Risk of corrosion damage from condensate
a) Install the exhaust air line such that condensate cannot collect.
Flexible aluminium hose
▪ Nominal diameter 40 mm (1.6 in)
▪ Maximum length of hose 2.5 m (8.2 ft)
▪ Temperature-resistant to 180°C (356°F)
Exhaust air connection
a) Connect hose to exhaust air connection fitting.
b) Route hose to the exhaust hood with a 3° rise.
c) Attach hose end 50-200 mm (2-7.9 in) under the exhaust hood.
d) Fill out the commissioning report at the end of this manual.