A
B
* Depends on the kitchen ventilation system and quality of ceiling material
** For service work 500 mm (19,69 in) recommended
The following clearances from walls, ceilings or other equipment must
be maintained when installing the unit:
Left, right and rear: at least 50 mm (1,97 in).
For service work 500 mm (19,69 in) on the left is recommended.
For parking the tray trolley, 800 mm (31,5 in) on the left.
Clearance from heat sources (baking oven), 500 mm (19,69 in) on
the left.
Clearance to deep-fat fryers, at least one length of the hand shower
at left and right.
Image: Minimum distance to devices with high heat radiation
Material damage to the device control due to excessive ambient
temperatures
Minimum distance to equipment with large heat radiation 510 mm (20'') on
right and left side.
These include, for example:
- Gas stoves
- Gas griddle plates
- Grills
- Deep fryers