Check Water Connection; Check Gas Connection; Check Flexible Hose Lines - Henny Penny FlexFusion FPG-221 Additional Installation, Operation And Maintenance Instructions

Hide thumbs Also See for FlexFusion FPG-221:
Table of Contents

Advertisement

Check water inlet in the cooking chamber for limescale residues
Test criteria
• Water inlet is free of limescale residues.
Check water inlet in the cooking chamber for limescale residues
Test criteria
If No
Decalcify or replace water inlet pipe.

8.7 Check Water Connection

Checking the flexible hose line on the unit
Test criteria
• Flexible hose line is tight (no deposits or corrosion).
If No
Change flexible conduit.

8.8 Check Gas Connection

Check gas connection line
Test criteria
• Firm fit with no damage, creases, or exposure to external heat sources.
In case of no.
Inform the operator: The device must not be operated
in a defective condition.
Do not carry out any further work.
Complete or schedule repair work.
Check external exhaust hood
Test criteria
• External exhaust hood is operational.
If no,
Inform store manager.

8.9 Check Flexible Hose Lines

Check the flexible hose line in the unit
Test criteria
• Clamps are screwed on tightly.
If No
Tighten bolts or replace clamp.
Maintenance instructions
Performing maintenance
Remarks / values
Remarks / values
Remarks / values
Remarks / values
Remarks / values
Remarks / values
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
31