Performing maintenance

8.10 Check waste water connection

Check the waste water connection on the unit
Test criteria
• On-site waste water connection to the unit is tight (no
deposits or corrosion).
If No
Repair wastewater connection.

8.11 Checking the condition of the electrical components

DANGER
Action
• Disconnect unit from power.
• Open side panel (see "Opening and closing the housing").
Check the unit for water residues
Test criteria
• Unit is free of moisture and water residues.
If No
Determine cause of moisture or water residue.
Stop cause.
If cause cannot be stopped immediately, take unit out of operation.
Check control board cable
Test criteria
• Wire insulation is undamaged (not brittle, swollen or
scorched).
• Connection wires appear OK externally (not damaged or
scorched).
Check contactor of the control board
Test criteria
• Contactor is externally OK (not brittle, damaged or
charred).
• Screw connections are tight.
32
Risk of personal injury and property damage from electric shock
• Before working on the unit, ensure that the unit has been disconnected from
the power supply.
Maintenance instructions
Remarks / values
Remarks / values
Remarks / values