Terminal Interfaces - Mitel MiVoice Office 400 System Manual

Hide thumbs Also See for MiVoice Office 400:
Table of Contents

Advertisement

Stranded
Wire diameter, core
Screening
Resistance
4.7.3

Terminal interfaces

The number of available terminal interfaces on the mainboard can be increased by fitting interface cards.
The RJ45 connector assignment is the same for interfaces of the mainboard and terminal cards.
4.7.3.1
DSI terminal interfaces
With interface cards EADP4 and the appropriate wiring adapters, DSI terminal interfaces can be made
available at the RJ45 sockets 1.x...4.x. The possible RJ45 sockets are highlighted in colour in the figure
below.
Figure 35: Connection possibilities for DSI terminal interfaces on single assigned RJ45 sockets
With interface cards 8DSI
available at the multiply assigned RJ45 sockets x.1 and x.2. The signals can be split again to individual
RJ45 sockets using patch cables and the fan-out panel FOP (see
assigned connecting cables (see e.g.
highlighted in colour in the figure below.
Figure 36: Connection possibilities for DSI terminal interfaces on multiply assigned RJ45 sockets
47
Not yet supported with Release 6.0
Release 7.1
System Manual for Mitel SMB Controller
47
and the appropriate wiring adapters, DSI terminal interfaces can be made
Prefabricated system cable 4 x
not required
0.4 ... 0.8 mm
not required
max. 2 X 250 W
Fan-out panel
RJ45).The possible RJ45 sockets are
Installation
FOP, ) or with 8-fold
124

Advertisement