Installation
FXS control input 1
any
Other conditions:
The same control inputs can control one or more switch groups.
The same switch group can only be switched by the 2 assigned control inputs.
Control of the switch groups using the control inputs takes priority over control using function codes.
4.7.3.3.1.6
One FXS interface per communication server can be configured for the connection of a general bell. It is
possible to use commercial auxiliary bells designed for connection in parallel to analogue terminals as
a general bell. However the impedance of the connected general bell (or total impedance in the case of
several devices connected in parallel) must not fall below 1 kW. The ringing voltage is 48 VAC. A 48 V
relay must be interposed when connecting a large number of auxiliary bells.
See also
"General bell on FXS interface" in the "System Functions and Features" System Manual.
4.7.4

Fan-out panel FOP

The interface cards 8DSI have four-fold assigned RJ45 sockets. With the fan-out panel FOP a total of 10
four-fold assigned RJ45 sockets can be split to individual RJ45 sockets.
The fan-out panel (FOP) takes up the space of one height unit in a rack and can be fitted directly above or
below the communication server.
147
FXS control input 2
On
FXS mode: General bell
Figure 55: Connection for FXS mode: General bell
Figure 56: Front panel, FOP fan-out-panel
Switch positions of the switch
group
Position 3
System Manual for Mitel SMB Controller
Release 7.1