Operating State And Error Displays - Mitel MiVoice Office 400 System Manual

Hide thumbs Also See for MiVoice Office 400:
Table of Contents

Advertisement

Operation and Maintenance
1.
The event message Charge counter overflow reaches the SRM server.
The communication server's system status in the SRM agent changes to Serious, and the
destinations turn yellow.
2.
The event message Fan failure reaches the SRM server.
The communication server's system status in the SRM agent changes to Critical, and the
destinations turn red.
3.
The event message Charge counter overflow is confirmed in WebAdmin in the Active event messages
view.
The system status of the communication server in the SRM agent remains on Critical, and the
destinations on red, because there is still an event message with this severity.
4.
The event message Fan failure reaches the SRM server.
The communication server's system status in the SRM agent changes to Normal, and the
destinations turn red.
After a first-start of the communication server, the SRM destination is automatically allocated event table 7.
The notification service to the SRM destination can be switched on or off.
On the SRM server the status modification per communication server must be allowed and configurations
are also required in WebAdmin. You can find a configuration guide in WebAdmin help under the Message
destinations.
6.5.1.3.8
To test the configuration, a test event message can be separately initiated for each destination in the
WebAdmin configuration (Message destinationsview). The event message is signalled without any delay,
directly at the selected signal destination.
If the communication server is connected via a modem or terminal adapter, the test event messages will be
signalled only once the connection is cleared down.
6.5.2

Operating state and error displays

6.5.2.1
System operating state
During the start-up phase, various self-tests are performed and the individual phases are shown in the LED
display on the front panel (see
When operation is OK, the SYS LED flashes green, regularly, and once per two second in the display
on the front panel. The system is in normal mode. Other operating states are signalled differently. This is
described in chapter
6.5.2.2
System error displays
Whenever the system detects an error, it displays the corresponding error code in the LED display field of
the front panel (providing the communication server is still powered and the display is working).
259
Testing the signal destination configuration
Start-up
mode).
Operating
modes.
System Manual for Mitel SMB Controller
Release 7.1