6Safety

6.1.2 External input/output signals that can be used for safety protection measures

Table 6-3 : External input/output signals that can be used for safety protection measures
Signal
External emer -
gency stop
Note1)
Door switch
Enabling device
input
Stop
Servo OFF
Automatic oper -
ation enable
Emergency stop
output
In servo ON
Waiting
In alarm
Note1) The external emergency stop input is prepared as a normal close for safety proposes. Thus, if the emergency stop
input circuit is opened when the robot is started up, the robot will not operate. Refer to
ples of safety
And, refer to
tings"for the function of the door switch input and the enabling device input.

6.1.3 Precautions for using robot

The safety measures for using the robot are specified in the "Labor Safety and Sanitation Rules". An outline of
the rules is given below.
(1) Robot installation
・ Secure sufficient work space required to safely perform work such as teaching and maintenance related to the
robot.
・ Install the controller outside the robot's motion space. (If a safety fence is provided, install outside the fence.)
・ Install the controller where the entire robot operation can be viewed.
・ Install display lamps, etc., to indicate the robot's operation state.
・ Securely fix the robot arm onto the fixing table with the designated bolts.
(2) Prevention of contact with operator
・ Install a safety fence or enclosure so that the operator cannot easily enter the robot's motion space.
・ Install an interlock function that will stop the robot if the safety fence or enclosure door is opened.
(3) Work procedures
・ Create and observe work procedures for the robot teaching, operation, inspection and emergencies.
・ Create hand signals to be followed when several operators are working together.
・ Create displays such as "Teaching in Progress" and "Inspection in Progress" to be put up when an operator is
in the robot's motion space so that other operators will not operate the operation panel (controller, control
panel).
(4) Training
・ Train the operators about the operations, maintenance and safety required for the robot work.
Safety
6-141
Connection
Parameter
point
Connector
-
(CR750 controller:
CNSUSR11/12)
(CR751 controller:
CNSUSR1)
-
-
Parallel I/O unit
STOP
or interface
SRVOFF
AUTOENA
Connector
-
(CR750 controller:
CNSUSR11/12)
(CR751 controller:
CNSUSR1)
Parallel I/O unit
SRVON
or interface
STOP
Connector
ERRRESET Outputs when an alarm occurs in the
CR750/CR751
-
controller:
(CNUSR2)
measures"for details.
Page 93, "(3) Automatic Operation/Jog Operation/Brake Release and Necessary Switch Set -
Functions
This servo power is shut off, and the
robot stops immediately.
The program execution is stopped, and
the robot stops. The servo power is not
shut off.
The servo power can be shut off.
Disables automatic operation when inac -
tive.
Outputs the input signal of external
emergency stop or emergency stop
switch of T/B turned on.
The servo power ON/OFF state is out -
put.
Outputs that the robot is temporarily
stopped.
robot.
Usage method
Externally installed emergency stop switch.
Door switch on safety protection fence.
Stopping at high-level error occurrence.
The door switch of the safe protection
fence
Enabling device.
The safety switch during teaching work
The robot is stopped when a peripheral
device fault occurs. The servo power is
not shut off.
The robot is stopped when a peripheral
device fault occurs. The servo power is
not shut off.
Door switch on safety protection fence
Display and warn the pilot lamp, the input
signal of external emergency stop or the
emergency stop switch of T/B turned on.
The servo power ON/OFF state is shown
and alerted with the display lamps.
The temporary stop state is shown and
alerted with the display lamps.
The alarm state is shown and alerted with
the display lamps.