Las-Light & Output Settings - Christie Mirage SST Technical Reference

Hide thumbs Also See for Mirage SST:
Table of Contents

Advertisement

LAS–Light & Output Settings
Configures the laser drive levels and uses the projector's LiteLOC
Commands
Command
Description
LAS+BLUP <value>
Changes the blue laser drive level. The
value sent to the laser illumination source is
reduced based on the maser laser power set
in LAS+POWR.
LAS+EBLU <0 | 1>
Enables or disables the blue laser on the
laser illumination source.
LAS+EGRN <0 | 1>
Enables or disables the green laser on the
laser illumination source.
LAS+EPOW <0 | 1>
Enables or disables all three (red, green,
and blue) lasers on the laser illumination
source.
LAS+ERED <0 | 1>
Enables or disables the red laser on the
laser illumination source.
LAS+GRNP <value>
Changes the green laser drive level. The
value sent to the laser illumination source is
reduced based on the maser laser power set
in LAS+POWR.
LAS+MAXA <value>
Sets the expected maximum ambient
temperature in Celsius.
LAS+POWR <value>
Adjusts the overall output of the lasers
without affecting the current white point.
LAS+REDP <value>
Changes the red laser drive level. The value
sent to the laser illumination source is
reduced based on the maser laser power set
in LAS+POWR.
Mirage SST Technical Reference–Serial Commands
020-103005-03 Rev. 1 (01-2021)
Copyright
©
2021 Christie Digital Systems USA, Inc. All rights reserved.
• If all individual laser enable commands
are disabled, this command is also
disabled.
• If all individual laser enable commands
are enabled, this command is also
enabled.
Serial API commands
feature.
Values
0 to 1000, where 1000 = 100% drive level
885 (Default)
0 = Disables the blue laser on the laser
illumination source
1 = Enables the blue laser on the laser
illumination source (Default)
0 = Disables the green laser on the laser
illumination source
1 = Enables the green laser on the laser
illumination source (Default)
0 = Disables all three lasers on the laser
illumination source
1 = Enables all three lasers on the laser
illumination source (Default)
0 = Disables the red laser on the laser
illumination source
1 = Enables the red laser on the laser
illumination source (Default)
0 to 1000, where 1000 = 100% drive level
990 (Default)
0 to 40
25 (Default)
0 to 1000, where 1000 = 100% drive level
500 (Default) = 50%
0 to 1000, where 1000 = 100% drive level
1000 (Default)
41

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mirage sst-6p

Table of Contents