Commands
Command
Description
SST?
Returns all status items. (Read-only)
Each item is listed in the following format:
(SST+<group>!<index> <state>
"<value>" "<description>")
SST+<group>?
Returns all status items within the specified
four-letter group identifier.
SST+<group>?
Returns a specific status item within the
<index>
specified four-letter group identifier. (Read-
only)
Examples
Display the temperatures:
(SST+TEMP?)
Result:
...
(SST+TEMP!000 000 "21 °C" "Integrator Rod Temperature (Temp 1)")
(SST+TEMP!002 000 "21 °C" "Air Intake Temperature (Temp 2)")
(SST+TEMP!003 000 "21 °C" "Lamp Exhaust Temperature (Temp 3)")
(SST+TEMP!020 000 "28 °C" "Environmental Board Temperature") ...
Return item 20 of the temperature group:
(SST+TEMP?20)
Result:
SST+TEMP!020 000 "28 °C" "Environmental Board Temperature"
SZP–Resize Presets
Changes the aspect ratio of the display.
By default, the projector maintains the aspect ratio and scale to either full width or full height
(whichever edge is reached first). 16:9 content is scaled to full height with pillar boxes.
Mirage SST Technical Reference–Serial Commands
020-103005-03 Rev. 1 (01-2021)
Copyright
©
2021 Christie Digital Systems USA, Inc. All rights reserved.
Serial API commands
Values
group = Provides the four letter identifier of
the Status System group the item belongs
to
index = Indicates the index value of the
status item within the group
state = Indicates the condition of the status
item:
000 = No errors or warnings
001 = Warning
002 = Error
value = Presents the value of the status
item
description = Provides the descriptive name
of the status item