Thread Clamp - VETRON 4000 Instruction Manual

Table of Contents

Advertisement

06.09. THREAD CLAMP

INDEX
MAX
A10
1
A29
3
T15
2000
D07
359
D08
359
O48
100
Thread clamp at turning back: clamp power on during turning back. The max. permissible time is set by T15 to protect
from damage.
Thread clamp at foot lifting: clamp power on during foot lifting. The max. permissible time is set by T15 to protect from
damage.
06.10. FOOT STROKE
-1-2
INDEX
MAX
S09
3500
S10
3500
S11
3500
S12
3500
S13
3500
S14
3500
S15
3500
A32
99
A35
1
A45
1
A83
199
O85
2
MIN
UNIT
0
-
0
-
1
ms
0
degree
0
degree
1
%
MIN
UNIT
500
rpm
500
rpm
500
rpm
500
rpm
500
rpm
500
rpm
500
rpm
0
stitches
0
-
0
-
0
0
-
DESCRIPTION
Thread clamp:
0 = OFF
1 = ON
Thread clamp option:
0 = Thread clamp only at start of seam
1 = Thread clamp at start of seam and at turning back
2 = Thread clamp at start of seam and with foot lifting
3 = Thread clamp at start seam, at turning back and with foot lifting
Thread clamp power on time with foot lifting or at turning back
Position for activating of the thread clamp
Thread clamp power o angle
Duty cycle in time period which PWM activation
DESCRIPTION
Limit speed for 1st stroke height
Limit speed for 2nd stroke height
Limit speed for 3rd stroke height
Limit speed for 4th stroke height
Limit speed for 5th stroke height
Limit speed for 6th stroke height
Limit speed for the maximum stroke height
Number of stitches for automatic switch o 2nd foot stroke
0 = Manual deactivated
N = Number of stitches after which the 2nd foot stroke is auto-
matically deactivated
Speed limit during quick stroke adjustment:
0 = No limit
1 = Limit
2nd stroke adjustment:
0 = OFF
1 = ON
Quick stroke height adjustment:
See chapter 06.18. A04 - 6
Type of stroke adjustment sensor:
0 = No
1 = Contact switch
2 = Potentionmeter
03/2023
YSC-90A0 INSTRUCTION BOOK
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

401040204030

Table of Contents