Soft Start; Turning Back - VETRON 4000 Instruction Manual

Table of Contents

Advertisement

06.03. SOFT START

INDEX
MAX
A21
1
S08
500
O01
10
Click „soft start" button
Functions: when beginning a new seam, speed is determined by the pedal and limited to the soft start speed.

06.04. TURNING BACK

INDEX
MAX
A13
1
O35
359
S16
500
T12
1000
Turning back ON: set A13 as to 1.
Function: turning back function starts after thread trimming. When the motor stops, wait the time which is set by T12.
The motor turns back at the speed which set by S16, and reaches the position which is set by O35.
06.05. CORRECTION
INDEX
MAX
A03
1
A30
1
D15
359
D16
359
O69
1
03/2023
28
YSC-90A0 INSTRUCTION BOOK
MIN
UNIT
0
-
200
rpm
1
stitches
. Is the icon on, the soft start is ON. Is the icon o , the soft start is OFF
MIN
UNIT
0
-
0
degree
50
rpm
1
ms
MIN
UNIT
0
-
0
-
0
degree
0
degree
0
-
DESCRIPTION
Soft start
0 = OFF
1 = ON
Speed of soft start
Number of soft start stitches
DESCRIPTION
Turning back
0 = OFF
1 = ON
Moving angle of rotation
Speed of turning back
Waiting time up to the turning back
DESCRIPTION
Stop position of correction:
0 = Half stitches
1 = One stitch
Correction mode:
0 = Single correction
1 = Continuous correction
Up position of correction
Down position of correction
Correction timing:
0 = The correction is inhibited after thread trimming
1 = No limit

Advertisement