04.03. FACTORY RESET

At Preparation and Test interface, press icon „Factory Reset".
Select: 1- „Parameter", 2-„Machine ZERO", 3-„Error record", 4-„Statistics" or all items to reset.
The machine needs to be restarted.
04.04. MACHINE ZERO POSITION
At Preparation and Test interface, press icon „Phase base by needle bar" or „Phase base by lever ".
The first option sets the base at highest position of the needle bar. The second option sets the base at the highest posi-
tion of the thread take up lever. Two options are equivalent.
04.05. CALIBRATE THE SENSOR OF FOOT KNOB
» At Preparation and Test interface, press icon „Stroke knob"
» Set the left upper feed dog adjustment knob to „5".
» Press „Next".
» Set the right upper feed dog adjustment button to "9" and the left knob also to "9".
» Press "Next".
» The configuration display appears.