Seam Center Guide - VETRON 4000 Instruction Manual

Table of Contents

Advertisement

06.10. FOOT STROKE
-2-2
INDEX
MAX
O76
500
O77
100
Adjust parameter of the speed limitation in relation to the sewing foot stroke: if parameter A35 set to 1, the speed is
reduced down to parameter S15 when 2nd stroke activated.
Number of stitches 2nd stroke o : if A32 is not 0, after sewing N stitches, the second sewing foot stroke is automati-
cally deactivated.
06.11. SECOND STITCH LENGTH
INDEX
MAX
A46
1
A83
199
S17
3500
O33
1
O78
500
O79
100
Adjust parameter of the speed limitation in relation to the 2nd stitch length: if parameter O33 set to 1, the speed is
reduced down to parameter S17 when 2nd stitch length activated.

06.12. SEAM CENTER GUIDE

INDEX
MAX
A47
1
A51
3
A83
199
O89
500
O90
100
03/2023
32
YSC-90A0 INSTRUCTION BOOK
MIN
UNIT
1
ms
1
%
MIN
UNIT
0
-
0
150
rpm
0
-
1
ms
1
%
MIN
UNIT
0
-
0
-
0
1
ms
1
%
DESCRIPTION
Full activation duration
Duty cycle in time period which PWM activation
DESCRIPTION
2nd stitch length adjustment
0 = OFF
1 = ON
Second stitch length:
See chapter 06.18. A04 - 8
Limit speed for the big stitch length
Speed limit during second stitch length adjustment:
0 = No limit
1 = Limit when big stitch length
Full activation duration
Duty cycle in time period which PWM activation
DESCRIPTION
Seam center guide:
0 = OFF
1 = ON
Mode for automatic raising of the seam center guide:
0 = Raising of seam center guide is deactivated; it is not raised auto-
matically.
1 = Raising of seam center guide when lifting the sewing foot
2 = Raising of seam center guide when sewing the backtack;
3 = Raising of seam center guide when sewing the backtack and
lifting the sewing foot
Seam center guide:
See chapter 06.18. A04 - 12
Full activation duration
Duty cycle in time period which PWM activation

Advertisement

Table of Contents
loading

This manual is also suitable for:

401040204030

Table of Contents