ID
DESCRIPTION
Water taken into tank when not
AF:28
required.
solenoid valve may have failed.
Water not draining from drain
AF:29
trap
AF:30
Max safety level reached
AF:41
P1 detergent intake anomaly
AF:42
P2 detergent intake anomaly
AF:43
Leak from dispensing system
Door opening detected with
AF:54
cycle in progress
Door locking system anomaly:
AF:56
door will not unlock or will not
lock
AF:73
Internal memory error
Restore fail. Problem on the
AF:78
motherboard.
User Manual
Check the water supply:
check that the water supply pressure is within the
permitted range.
A
water
intake
Also check that there no leaks from the device (no water
around it).
If there are leaks: turn off all water supply taps at once and
contact the after-sales service.
Check the connection to the water drain,
and if possible inspect the drain for obstructions or
blockages.
Check the device's water supply:
1. Intake pressure.
2. That connections have been made correctly, as
instructed in this manual.
If there are leaks: turn off all water supply taps at once and
contact the after-sales service.
1. Check that the detergent intake nozzle is correctly positioned
in the can.
2. Check for detergent leaks (pools of detergent around the
device).
Check that the detergents have not passed their use-by date and
are not crystallised. Possible chemical dispensing problems.
Inspect the load carefully to ensure that it is clean at the end of
the cycle. Report the problem to the after-sales service.
1. Check for detergent leaks (pools of detergent around the
device).
2. Inspect the load carefully to ensure that it is clean at the end
of the cycle. Report the problem to the after-sales service.
1. Ensure the door is closed properly before running a
washing cycle.
2. Do not force the door open with a cycle in progress;
always use the buttons provided on the device to stop a
cycle and open the door.
3. Check there is nothing between the door and the device's
chamber preventing the door from closing properly.
Always ensure the door is closed properly before running a
washing cycle.
Try opening the device again with the Open door button.
If necessary, use the manual / emergency door release
procedure described in the manual.
User: follow the DEFAULT PROCEDURE described above. If
the alarm does not disappear, follow the RESET
PROCEDURE.
User: follow the DEFAULT PROCEDURE described above. If
the alarm does not disappear, follow the RESET
PROCEDURE.