Electrical Connections; 50 Hz Version; Ambient Conditions - Smeg BPW1260 User Manual

Bedpan washers – hospital sector
Hide thumbs Also See for BPW1260:
Table of Contents

Advertisement

15.1.2 ELECTRICAL CONNECTIONS

15.1.2.1 50 Hz version

Connection to 400 V three-phase with neutral – Standard*
Standard power supply:
Electrical protection within system:
Connection to 230 V three-phase without neutral [-3]
Power supply:
Electrical protection required within system:
Connection to 230 V single-phase, lower power [-1]
Power supply:
Electrical protection required within system:
* The electrics of the standard version can be configured, by technical staff authorised by the
manufacture, for the following power supply types:
- three-phase without neutral;
- single-phase, lower power.
15.1.2.2 60 Hz version
Connection to 380 – 400 V three-phase with neutral – Standard 60 Hz*
Standard power supply:
Electrical protection within system:
Connection to 220 – 230 V three-phase without neutral [-36]
Power supply:
Electrical protection required within system:
Connection to 220 – 230 V single-phase, lower power [-16]
Power supply:
Electrical protection required within system:
* The version with power supply three-phase 400 V 3N~ (with neutral) can be configured on site, by
engineers authorised by the manufacture, for the following power supply types:
-
Three-phase 230 V 3~ (without neutral)
-
Single-phase 230 V~

15.1.3 AMBIENT CONDITIONS

Use
Max altitude
Temperature [min – max]
Minimum lighting level required
Max humidity
Installation category (or surge category)
Electrical insulation class (ref. IEC 61140)
Degree of pollution
Heat emission – device to room, max
Max noise level
User Manual
80% for temperatures up to 31 °C with linear decrease to 50% at the
temperature of 40 °C.
193909105 rev.02
400 V 3N~ / 50 Hz / 8 A / 4500 W
230 V 3~ / 50 Hz / 13 A / 4500 W
230 V ~ / 50 Hz / 14 A / 3300 W
380 – 400 V 3N~ / 60 Hz / 8 A / 4500 W
220 – 230 V 3~ / 60 Hz / 13 A / 4500 W
220 – 230 V ~ / 60 Hz / 14 A / 3300 W
Indoor
Up to 2,000 m above sea level
From 5 °C to 40 °C
300 lx
II
I
2
700 W
<60 dB (A)
BPW1260
3P+N, 16 A
3P, 16 A
1P+N, 16 A
3P+N, 16 A
3P, 16 A
1P+N, 16 A