Quantum ATL M1500 User Manual page 134

Atl m-series
Hide thumbs Also See for ATL M1500:
Table of Contents

Advertisement

Appendix B Fault Symptom Code (FSC) Dictionary
FSC
Name
2021
FSC_INVALID_PACKET_
8
2022
FSC_NOT_
IMPLEMENTED
2023
FSC_DRIVE_NO_
RESOURCE
2024
FSC_COMMAND_
FAILED_1
2025
FSC_COMMAND_
FAILED_2
2026
FSC_COMMAND_
FAILED_3
2027
FSC_COMMAND_
FAILED_4
2028
FSC_COMMAND_
FAILED_5
2029
FSC_COMMAND_
FAILED_6
116
Description
Invalid packet received
from drive 8
The requested function
is not implemented in
the drive type
Couldn't get
semaphore from OS
Response packet
received from drive 1
indicates command
failed
Response packet
received from drive 2
indicates command
failed
Response packet
received from drive 3
indicates command
failed
Response packet
received from drive 4
indicates command
failed
Response packet
received from drive 5
indicates command
failed
Response packet
received from drive 6
indicates command
failed
ATL M-Series User's Guide
FRU Name
Confidence %
Drive
100%
Drive
100%
Microcode
100%
Drive
100%
Drive
100%
Drive
100%
Drive
100%
Drive
100%
Drive
100%

Advertisement

Table of Contents
loading

This manual is also suitable for:

Atl m2500

Table of Contents