Christie CP4230 Service Manual page 127

Hide thumbs Also See for CP4230:
Table of Contents

Advertisement

EXAMPLES:
(LPF+C101 "Default") Set lamp file for channel 1 to file "Default"
(LPF?L) List all available lamp files
(LPF 1) Set lamp file for current channel to index 1 in file list
Lamp Hours (LPH)
Get information on installed lamp. Read only control.
SUBCODE
DESCRIPTION OF USE
FLSK
Return total failed lamp strikes on the installed lamp
FRSK
Return total failed lamp restrikes on the installed lamp
LPOF
Return total lamp unexpected off times on the installed lamp
NONE
Return lamp usage for current lamp in hours.
TLSK
Return total lamp strikes on the installed lamp
EXAMPLES:
(LPH?) Get usage in hours
(LPH+FLSK?) Get lamp strikes
Lamp Intensity (LPI)
Set lamp intensity setpoint. The value is used when lamp mode is set to LiteLOC™. The projector will adjust the
Lamp Power to maintain this intensity. NOTE: This command can only be used to update the current lamp file.
Changing the lamp intensity for the current channel will change the lamp intensity for any channel using the same
lamp file.
SUBCODE
DESCRIPTION OF USE
Cxxx
Replace Cxxx with the channel number. Valid range is 101-164.
NONE
Set lamp intensity for the current channel.
EXAMPLES:
(LPI 4500) Set lamp intensity to 4500 for current channel
(LPI+C103 4000) Set the lamp intensity to 4000 for channel 3
(LPI?) Get lamp intensity for the active channel
Lamp Life (LPL)
Set/get expected lamp life in hours. The default hours will be used if lamp life is 'not set'. Lamp expiry message
will be sent out when lamp usage is over the lamp life.
SUBCODE
DESCRIPTION OF USE
LIFE
0 - No warning will be generated.
1 - Lamp Life Expiry Warning will be generated when lamp hours extends past lamp life. Warning will be
reported in SST. Warning will be cleared by extending lamp life or changing the lamp.
NONE
Set or get expected lamp life.
ROTA
Set to 1 acknowledge the Lamp Rotation Warning. Will auto clear at lamp life or on lamp change.
ROTW
0 - No warning will be generated.
1 - Lamp Rotation Warning will be generated when lamp hours extends past 1/2 lamp life. Warning will be
reported in SST. Warning will be cleared by LPL+ROTA or changing the lamp.