iLABELx,y
where i is the device type and ID, x is the label specifier, and y is the label text (to set the label) or a
? character (to query the label). The label specifiers are as follows:
Label Specifier
D
SG
I1, IA, IB, IT
O1, OA, OB, OT
P, W, X, Y, Z
PB0-PB7, WB0-WB7, XB0-XB7, YB0-YB7,
ZB0-ZB7
PM0-PM1, WM0-WM2, XM0-XM2, YM0-
YM2, ZM0-ZM2
R1
G0-G3
LI1-LI24
LO1-LO20
P0-P47
M0-M255
The text of each label can be up to 16 characters long. Labels for presets 0-15 are read-only.
This command is saved to global non-volatile memory and is not part of a preset. Its value is saved
each time it is changed. It will retain its value after power-down. Since this command writes to non-
volatile memory, there will be a delay before an acknowledgment is returned.
Example
S01LABELOB,Zone 2 Speaker
S01LABELOB,?
8.68. LAGC -- Enable or Disable Line Input Automatic Gain
Control
This command sets or queries the status of the Automatic Gain Control (AGC) algorithm on input
channels A-B.
Description
A label for the device itself.
A label for the signal generator.
Labels for the input channels.
Labels for the output channels.
Labels for matrix outputs to EF Bus.
Labels for inputs from EF Bus to submatrices.
Labels for outputs from EF Bus submatrices to main
matrix.
Label for AEC reference.
Labels for logic input groups.
Labels for logic input pins
Labels for logic output pins
Labels for user presets.
Labels for user macros.
Description
Set label of output B
to "Zone 2 Speaker".
Query label for
output B .
Status Message
S01LABELOB,Zone 2 Speaker
S01LABELOB,<string> , where
<string> is the current label assigned to
output B .