This command executes the preset corresponding to the specified number, which must be between 0
and 47. The preset must either be a pre-defined factory preset (0 - 15) or a user preset (16 - 47) that
has been previously defined via the
error condition of ERROR#070 will be returned. If one or more of the commands in the preset
generated errors, then an error condition of ERROR#072 will be returned.
When the PRESETQ command executes, status messages for all of the commands in the preset will
not be generated. The PRESETQ command is provided so that a control system can execute a preset
and not generated heavy data traffic from the resulting status messages. Of course, this assumes that
the control system is not interested in any of the acknowledgements. The
used to execute the preset without suppressing the status messages.
Example
Description
Execute preset number 18 without generating any status
S01PRESETQ18
messages.

8.135. PRESETW -- Save a Preset

This command writes the current settings of the device into the user preset with the specified number.
Since the factory presets (0 - 15) are read-only, an ERROR#071 will be generated if they are specified
in the PRESETW command.
Once a preset it saved, it can be recalled via the
also be set to be executed automatically at power-up via the
This command is saved to global non-volatile memory and is not part of a preset. Its value is saved
each time it is changed. It will retain its value after power-down. Since this command writes to non-
volatile memory, there will be a delay before an acknowledgment is returned.
Example
S01PRESETW18

8.136. PRESETX -- Execute a Preset

This command executes the preset corresponding to the specified number, which must be between 0
and 47. The preset must either be a pre-defined factory preset (0 - 15) or a user preset (16 - 47) that
has been previously defined via the
error condition of ERROR#070 will be returned. If one or more of the commands in the preset
generated errors, then an error condition of ERROR#072 will be returned.
When the PRESETX command executes, status messages for all of the commands in the preset will be
generated (unless
acknowledgement mode
using the
command, which is exactly the same as the PRESETX command except that
PRESETQ
status messages are suppressed.
PRESETW
Description
Save the current device settings as preset 18.
PRESETW
command. If the specified preset is empty, then an
and
PRESETX
PRESETQ
PRESETP
command. If the specified preset is empty, then an
is turned off). The status messages can be suppressed by
command can be
PRESETX
Status Message
S01PRESETQ18
commands. The preset can
command.
Status Message
S01PRESETW18