Set gain on output channels 1
and T to 0 dB, and gain on
S01GAINO*äììä
output channels A and B to 9 dB.
Query gain settings on all output
S01GAINO*?
channels (1, A, B, T) .
8.60. GAINP -- Set Phone Output Gain
This command sets the gain of the output to the phone interface. This command is an alias for the
GAINOT. It is provided for backwards compatibility with and ease of migration from the EF200. When
possible, the
GAINOT
This command is an integer command. See
command. The minimum and maximum values for this command are -100 and 20, respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example
Description
S01GAINP6 Set phone output gain to 6 dB.
S01GAINP>3 Increase phone output gain by 3 dB.
S01GAINP? Query phone output gain.
8.61. GAINSIT -- Set From Phone User Tone Gain
This command sets the gain of the user tones coming from the phone DSP. User tones include entry
and exit tones (see TONEE) and custom tones (see the
cases, the tones are played out "locally" and their gains are adjusted by the GAINSIT command.
Sometimes, the tones are played out to the phone, and the gain is adjusted by the
command.
This command is an integer command. See
command. The minimum and maximum values for this command are -20 and 20, respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command
command should be used instead of this command.
S01GAINO*äììä
S01GAINO*abcd, where a-d are each
between <space> and ÿ, depending on the
current setting of the gains for each of the ten
output channels (1, A, B, T).
Section 6.2
for more information on this type of
Status Message
S01GAINP6
S01GAINPx , where x is the new value of the
phone output gain. If this command was issued
after the example above, then the status
message would be S01GAINP9 .
S01GAINPx , where x is the new value of the
phone output gain. If this command was issued
after the example above, then the status
message would be S01GAINP9 .
SOUNDP
Section 6.2
for more information on this type of
and
commands). In most
SOUNDL
GAINSOT
Need help?
Do you have a question about the Vortex EF2211 and is the answer not in the manual?