UPS5000-S-(350 kVA-800 kVA)
User Manual
Case
Issue 12 (2023-05-26)
Symptom
NO TE
For details about component replacement and maintenance involved in Troubleshooting
and Alarm List, consult Huawei maintenance engineers.
Copyright © Huawei Digital Power Technologies Co., Ltd.
Possible Cause
The bypass module
experiences
overtemperature.
7 Troubleshooting
Measure
Reduce the load, or
improve ventilation.
271