Maximum Frame Rate

The maximum frame rate is as follows depending on the sensor's scanning range and the GigE
bandwidth.
Note: The Frame Rate Calculator, which calculates the maximum frame rate, is available for
download from the product page on the JAI website (www.jai.com).

Maximum Frame Rate Period Formula

During continuous operation (Frame Start trigger is Off or Exposure Mode is Off)
Maximum frame rate of sensor output
l
SensorFR = 1/((Height_s + 40)×Hperiod)
Maximum frame rate of GigE output bandwidth
l
InterfaceFR = 920 × 1000000/(Height_g × Width_g × Pack value)
Maximum frame rate
l
FR_Cont = Min (SensorFR, InterfaceFR)
When Frame Start trigger is On and Trigger OverLap is Off
Maximum frame rate of sensor output
l
Sensor FR = 1 / {H Period × (Height + 40)}
Maximum frame rate by interface
l
- 44 -