Delayed ReadOut

Delayed readout enables images captured by a Frame Start trigger command to be stored inside the
camera and read out on demand at a later time using Acquisition Transfer Start trigger. This can be
especially useful when multiple cameras need to be triggered at the same time, but simultaneous
readout of all images would overwhelm the available network bandwidth. The delayed readout buffer
can hold up to 7 frames in 8-bit mode or 3 frames in 10-bit or 12-bit modes.
Note: For details, see

ALC (Automatic Level Control) Function

Related Setting Items:
The ALC (automatic level control) function combines the automatic gain control (AGC/Auto Gain
Control) and automatic exposure control (ASC/Auto Shutter Control) functions, and is capable of
handling various changes in brightness.
The function operates as follows in response to changes in brightness.
If the lighting condition is changed from bright to dark ASC ― AGC
l
If the lighting condition is changed from dark to bright AGC ― ASC
l
To Use the ALC Function
Set Gain Auto or Exposure Auto or both to Continuous mode. Configure the minimum value,
maximum value, etc. for AGC and ASC under JAI Custom Control ALC. The target video levels for
AGC and ASC are configured in ALC Reference. For example, when ALC Reference is set to 100%,
video levels will be maintained at 100% for AGC and ASC.