When fully inserted, fix the switch by closing the remaining 2 screws in the middle and
Step 7.
tightening the 8 screws inserted in Step 2 with a torque of 4.5±0.5 Nm.
2.5.2.1 Removing the System from the Rack
 To remove a unit from the rack:
Turn off the system and disconnect it from peripherals and from the electrical outlet.
Step 1.
Unscrew the two M6 screws securing the front of the inner rails' ears to the outer rails and
Step 2.
to the rack.
Pull the unit out until braking is felt. For safety purposes, the locking mechanism will not
Step 3.
allow a complete removal of the unit at this stage.