CC (Command Sequence Character) command
<AT Command Mode Options> The CC command is used to set/read the ASCII character used between guard times of
the AT Command Mode Sequence (BT + CC + AT). This sequence enters the module into AT Command Mode so that
data entering the module (from the host) is recognized as commands instead of payload.
AT Command: ATCC
Binary Command: 0x13 (19 decimal)
Parameter Range: 0x20 - 0x7F
Default Parameter Value: 0x2B (ASCII "+")
Number of bytes returned: 1
Related Commands: AT (Guard Time After), BT (Guard Time Before)
CD (GPO2 Configuration) Command
<Serial Interfacing> CD Command is used to select/read the behavior of the GPO2 line (pin 3).
AT Command: ATCD
Binary Command: 0x28 (40 decimal)
Parameter Range: 0 - 8 (standard rates)
Parameter
0
1
2
3
4
Default Parameter Value: 2
Number of bytes returned: 1
XTend RF Module User Guide
Configuration
RX LED
Default High
Default Low
(reserved)
RX LED (valid address only)
Command descriptions
33