Shutdown; Start; Stop - Cisco 1120 Installation Manual

Secure access control server
Hide thumbs Also See for 1120:
Table of Contents

Advertisement

Commands

shutdown

To shut down the CSACS 1120 from the serial console, use the shutdown command:
shutdown
Syntax Description
This command has no arguments or keywords.
Example
The following command shuts down the appliance:
shutdown

start

To start one or more of the ACS services, use the start command:
start [ service name(s)]
Syntax Description
This command uses as an argument the name of the service or services to be started.
Usage Guidelines
Use the start command to start any ACS service. You can determine the status of each service by using
the show command. For more information, see
Example
The following command restarts the CSAuth and CSAgent services:
restart csauth csagent

stop

To stop one or more of the ACS services, use the stop command:
stop [ service name(s) ]
Services subject to this command are halted until they are restarted again, which may interfere with
Note
AAA services.
When you stop the CSAgent service, not only does the CSACS 1120 stop CSAgent, but it also changes
Note
the startup type to manual. This action has the effect of keeping it stopped; even after reboot. Likewise,
starting CSAgent resets the startup type to automatic.
Installation Guide for the Cisco 1120 Secure Access Control Server 4.2