Fortis System Installation Drawing - Standard End Caps - Renishaw FORTiS-N Installation Manual

Enclosed encoder system
Table of Contents

Advertisement

12.5 FORTiS system installation drawing – standard end caps
B
5
P1
P2
28.7 ±0.5
32.2
C
1 ±0.1
D
13
18
//
0.1
B
0 ±0.2
D
1
The parallelism between the machine
guideway and the mounting surface
from P1 to P2 should be under 0.1 mm.
Dowel pins should ideally be located
on P1 and P2. Other positions are
permissible (not on endcaps).
KEY
C = Compressed air inlet fitting
D = Required mounting dimensions
L = LED set-up illumination
ML = Measuring length
P = Gauging points for alignment
S = Start of measuring length
X = Machine guideway/axis datum
22
FORTiS-N Functional Safety enclosed encoder system – original instructions
11.5
80 ±5 ML ≥ 120
D
40 ±5 ML < 120
13.5
Both
L
sides
4
56
D
12
2 × Ø4.5
//
0.1 CZ
17.5 ±2
96
113
S
ML
70
120
170
220
270
320
370
(ML 320 mm shown)
(ML + 138) ±0.4
(ML + 115) ±0.4
D
P1
P2
1
P1
//
0.1
X
X
ML
4.5
18.2 ± 0.2
420
470
520
570
620
670
720
770
Dimensions and tolerances in mm
P2
80 ±5 ML ≥ 120
40 ±5 ML < 120
Ø9.6
Ø15
6
820
920 1020 1140 1240 1340 1440 1540 1640 1740 1840 2040
B
C
1 ±0.1
D
//
0.1
B
0.25 ±0.2
D
18.25 ±0.05
//
0.1
X
0.05

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fortis-s

Table of Contents