Turn Machine On - Rancilio EGRO 55 Series Technical Manual

Table of Contents

Advertisement

2.2 - 2.12 INSTALLATION INSTRUCTIONS: STEP BY STEP GUIDE
2.8 CONNECT THE MACHINE TO POWER SUPPLY
PLEASE NOTE: The Egro 55 series machine requires a NEMA L6-30R receptacle. The optimal voltage supply is 230V. An acceptable
range of voltage is 208V - 250V. If the power supply does not produce 208V of steady voltage, a voltage booster is required. If the
power is above 250V, a buck'n boost transformer may be required.
The Egro machines do not use a neutral line. A dedicated ground wire is required for proper performance.
1. Locate the power cable of the machine.
2. Plug machine into NEMA L6-30R receptacle.
2.9 TURN THE MACHINE ON
WARNING: BE SURE THAT THE MAIN WATER SUPPLY TO THE MACHINE IS TURNED ON.
1. Raise the coffee spout to the highest position.
2. Move the steam wand to the left.
3. Move the hot water outlet upward.
4. Open the ground drawer door.
5. Remove the plastic ground drawer.
6. Flip the power switch to the on (I) position.
7. Replace the ground drawer and close grounds drawer door.
ATTENTION: DO NOT ATTEMPT TO PROGRAM THE MACHINE UNTIL THE MACHINE IS READY.
When the machine is turned on, it must go a heating and rinsing initialization. During this time do not enter programming
otherwise an error may occur. You may enter programming after the screen reads "Please Select".