3.5 CONFIG 2 MENU
Confi g 2 Menu contains parameters for making adjustments to the machine that do not effect the specifi c drink parameters.
Product Total
Cleaning request function. Use this feature to set a cleaning alert after a specifi ed number of drinks have been
produced. The alert will remain on the screen until the cleaning has been carried out.
C-Request
Specifi es whether the steam boiler should be fi lled with or without using the machines pump. If the water line is not
pressurized, or it does not have enough pressure this should be set to 0.
S-Filling
Enables or disables the erase function in the product counter menu.
PT-Clear
Identifi es the type of steam wand that is present on the machine.
SOFTWARE VERSIONS 1.00 - 2.09
Auto-Steam
Specifi es the temperature in Celsius at which the TS wand will shut off.
Ref. Temp. AS
(Options: 40 - 99 C)
iButton Foam
iButton Foam: This submenu contains the programming for the temperature and emulsion levels of the cappuccino
button or left side button on the iSteam wand.
Use this parameter to set the fi nal temperature of the steamed and frothed milk for the cappuccino button on the
Temperature
iSteam wand. This temperature is in Celsius.
Use this parameter to set the emulsion level or foaming level associated with the cappuccino button on the
E-degree
iSteam wand. OPTIONS: 0 - 6.
process and shut air off prior to reaching the fi nal temperature. For example, if you set this parameter to 5 the iSteam will begin
steaming with air infused, shortly before it reaches it's fi nal temperature it will stop infusing air and simply steam. This will result in
possibly less foam, but the foam may be "tighter".
© Copyright 2008. Rancilio North America
Products...
0 = No cleaning alarm
1 - 1000 = number of drinks before alert is displayed
0 = Fills with machine's pump
1 = fi lls without machine's pump
0 = Erasing not possible
1 = Erasing possible
0 = NO TS wand present
1 = TS wand is present
ISTEAM SETTINGS: ONLY VALID WHEN ISTEAM WAND IS PRESENT
0 = no foam or no air during steaming
6 = maximum foaming or air from the beginning to the end of steaming
Config1...
SOFTWARE VERSIONS 1.00 - 2.09
0 = NO TS wand present
1 = TS wand is present with steam pressure control
2 = TS wand without steam pressure control
3 = iSteam wand present
PLEASE NOTE: For all settings 1, 2, 3, 4, and 5, the iSteam will add air to the steaming