3.4 CONFIG 1 MENU
Confi g 1 Menu contains parameters for making adjustments to the machine that do not effect the specifi c drink parameters.
Product Total
Specifi es the total number of drinks that can be queued or preselected in modes 1 and 2.
Presel. Mode1
In a self service application this parameter must always be set to =1.
Presel. Mode2
Enables or disables the minimum brew-time functions. If the brewing time is too slow, a "CHECK WATER" message
will appear on the display screen.
W_Control
P1 Turns
DO NOT CHANGE! Factory setting of the position of the top brewing piston.
P2 Out
Defi nes the time for starting the automatic rinsing programme after the last milk
Cap.Aut.Rinse
beverage has been made. (Only available with the automatic milk rinsing option)
Min. value 0 --- Max. Value 30
Contains a list of submenu that changes the MLR (Milk Line Rinsing parameters to
MLR-Param.
accommodate for longer milk delivery lines. (For example, with an under counter fridge.)
Corr. Time
Rinsing Time
Blowing out time
Air Foam Valve (AFV): this setting needs to be set if the AFV is present on the 5513
AFV
machine. AFV is the removable mechanical check valve located just above the
frother heads (beneath the SS slider cover).
APPLIES ONLY TO MACHINES THAT HAVE VERSION 2.10 OR HIGHER SOFTWARE.
Notifi es the machine if the new generation brewing unit is present in the machine.
NBUP
APPLIES ONLY TO MACHINES THAT HAVE VERSION 2.10 OR HIGHER SOFTWARE
Enables or disables steam boiler emptying feature. If enabled the steam boiler will be emptying during the coffee
B-Emptying
cleaning and fi lled up again at the end of the coffee cleaning program.
© Copyright 2008. Rancilio North America
Products...
PLEASE NOTE: 1 = No drink queuing possible. (Options 1 - 16)
0 = Disabled
1 = Enabled
0 = switched off
1 - 15 = time interval in minutes
Increases the cap. Time (correction time) after the automatic MLR-rinse
Rinse time can be used to increase water rinsing of the milk pipes by MLR max. 9.9 seconds
Blow out time can be used to increase the time that air is blown through milk pipes by MLR
max. 9.9 seconds.
AFV = 0 Air foam-valve not present
AFV = 1 Air foam-valve present
0 = Not present
1 = New brew unit present
0 = Disabled
1 = Enabled (boiler will empty)
Config1...
- Section 3: Page 13 -
EGRO 55 SERIES TECHNICAL MANUAL
Config2...
Service...
USED FOR
MODEL 5513
ONLY
USED FOR
MODEL 5513
ONLY
USED FOR
MODEL 5513
ONLY
E55_TM_programmingV3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Egro 5511Egro 5513

Table of Contents