Error List - Rancilio EGRO 55 Series Technical Manual

Table of Contents

Advertisement

3.8 ERROR LIST

3.8 ERROR MESSAGES: When the machine has encounters a problem with one of it's components
it will give the end user an error message. Technicians can check the list of errors the machine has
encountered and the number of cycles the machine had performed when the error occurred. SEE PAGE
18 OF THIS SECTION FOR MORE DETAILS ON HOW TO ACCESS THE ERROR LIST.
NO.
DESCRIPTION
1
Error in EEPROM
31
Coffee boiler could not be refi lled.
33
Steam boiler could not be refi lled.
41
Coffee boiler does not heat up
43
Steam boiler does not heat up
61
No signal from Flowmeter P1
71
Brew duration is greater than 90
seconds
73
Delivery time for tea takes too long
81
No signal from upper piston
82
No signal from lower piston
91
Upper Piston
P1: Time to pressure > 8 seconds
P1: Time to ejection > 5 seconds
92
Lower Piston
P2: Time to pressure > 8 seconds
P2: Time to ejection > 5 seconds
© Copyright 2008. Rancilio North America
Turn machine off, wait 30 seconds and turn on again.
a. Check main water supply and pump - is there water going to the machine?
b. The pump pressure is too high, greater than 10 bar
c. Brew valve Y1 does not close - check in monitor menu
d. Flowmeter P1 is faulty - check using monitor menu
e. Expansion/non-return valve is blocked
f. Boiler inlet is blocked - remove inlet and visual check
a. Check main water supply and pump - is there water going to the machine?
b. Level sensor B3 is calcifi ed or has electrical fault - check using monitor menu
c. Valve Y3, has a mechanical or electrical fault - check using monitor menu
d. Non return valve or inlet pipe is blocked - remove and visual check
a. Check temperature fuse F11
b. Check semiconductor element K1
c. Check Heater/Connection X2
d. Check temperature sensor NTC B1 / Connection J11 Pin 1/2
e. Check and make sure one phase of the power supply is not missing
a. Check temperature fuse F21
b. Check semiconductor element K2
c. Check Heater/Connection X2
d. Check pressure switch S13 using monitor menu
e. Check and make sure one phase of the power supply is not missing
a. Flowmeter is clogged or not responding - check using monitor menu
b. Expansion or non-return valve is clogged - visually check
c. Coffee boiler, inlet or outlet is blocked - visually check
d. Brew valve (Y1) is blocked - check using monitor menu
e. Sieve from upper or lower piston is blocked - visual check
f. Flow limiter from brewing piston is blocked
a. Coffee is set to grind to fi ne - adjust grinder to courser setting
b. Sieve from upper or lower piston is blocked - visually check
c. Check piston height from brew piston P2 (Confi g. 1 menu P2 height)
d. Flow rate or pressure from water pump to low - increase pump pressure
a. Pipe or sieve is blocked - visually check
a. No signal from limit switch S15 (upper piston motor P1) - check in monitor menu
b. Upper piston P1 is jammed - visually check
c. Upper spindle motor M7 /limit switch is faulty - check in monitor menu
d. Check cable connections M7 to J2
e. Grounds ejector arm is blocking the movement of upper piston - visually check
a. Lower piston P2 is jammed - visually check
b. Spindle motor M8 limit switch S17 is faulty - check in monitor menu
c. Check cable connections M8 to J3
a. Upper piston P1 is jammed - visually check - use monitor menu
b. No signal from upper spindle motor M7/Revolution counter S14 - use monitor menu
c. Check cable connections M7 to J2
a. Lower piston P2 is jammed - visually check - use monitor menu
b. No signal from lower spindle motor M8 / Revolution counter S16
c. Check cable connections M8 to J3
- Section 3: Page 23 -
EGRO 55 SERIES TECHNICAL MANUAL
SOLUTION
E55_TM_programmingV3