Service Menu - Rancilio EGRO 55 Series Technical Manual

Table of Contents

Advertisement

3.6 SERVICE MENU

Service menu is for maintenance and diagnostics. It contains information as well as component diagnostic tests.
Product Total
Submenu which contains last errors machine encountered.
Last Errors
Error
Displays the total brewing cycles of the life of the machine. This setting is not reset-able.
Cycles
P-Serv
Displays the number of brewing cycles since the last CLR-P Serv.
Specifi es the number of brewing cycles after which the machine requires Preventative Maintenance be performed.
When the machine has reached this number, it will alert the user with a "COFFEE SERVICE" message on the
Max cycles
display.
(Options: 0 - 99 --- These are in increments of 1000 cycles, example 1 = 1000. - 15 = 15,000)
CLR P-Serv
Clears the P-Serv counter and set it to zero.
Displays the volume of water used in m
W-Serv
Specifi es the volume of water after which the water softener cartridges should be replaced. When this volume has
be reached the machine will alert the user with a "WATER SERVICE" message. Water volume is calculated by m3.
Max. Flowm
(Options: 0=disabled - 99)
CLR W-Serv
Clears the W-Serv counter and set it to zero.
Displays the number of coffee cleanings since the last CLR R-Serv.
C-Cleanings
© Copyright 2008. Rancilio North America
Products...
Displays the last 64 error messages that the machine encountered,
and how many cycles the machine had performed when the error
occurred.
Config1...
3
since the last CLR W-Serv.
- Section 3: Page 18 -
EGRO 55 SERIES TECHNICAL MANUAL
Config2...
E061
Error Number
Service...
18200
Error Number
E55_TM_programmingV3