Rancilio EGRO 55 Series Technical Manual page 40

Table of Contents

Advertisement

3.5 CONFIG 2 MENU
Confi g 2 Menu contains parameters for making adjustments to the machine that do not effect the specifi c drink parameters.
Product Total
Uploads the settings from a service card to the Products, Confi g1, and Confi g2 menus of the machine.
Load Card?
ONLY VALID WITH A CARD READER ATTACHED TO THE MACHINE.
Overwrites the current settings in Products, Confi g1 and Confi g2 with factory default settings.
Load Defaults
DO NOT USE OR YOU WILL HAVE TO REPROGRAM THE ENTIRE MACHINE!!
NOT USED IN USA! Enables or disables loading of drink prices into a CCI peripheral.
Price=> CCI
Enables or disables the Shift (#1) button. Enable when DECAF is an option.
Shift
NOT USED IN USA! Enables or disables the Choko function.
Choko
Enables or disables the Milk sensor, Bean sensor, and Grounds counter feature.
feature is available in the USA. It measures the grounds in the brew chamber, if there is not enough to brew the selected drink it
MB_Sensor
displays a "Check Beans" message.
Applies to software versions 1.0 - 2.09
Turns beeper ON or OFF.
IMS Beeper
NOT USED IN USA! Enables or disables cleaning when machine's in operating mode 2.
R-Mode 2
Specifi es which MLR (Milk Line Rinsing) System is being used.
MLR_Type
© Copyright 2008. Rancilio North America
Products...
0 = Disabled
1 = Enabled
0 = Disabled
1 = Enabled
0 = Disabled
1 = Enabled
0 = Grounds counter feature Enabled
1 = Milk, Bean sensor and Grounds counter enabled
2 = Only Milk sensor enabled
0 = ON
1 = OFF
0 = rinsing disabled
1 = rinsing enabled
0 = none MLR
1 = MLR 1. Older generation rinsing with Hose cleaning
2 = MLR 2. Older generation rinsing without Hose cleaning
3 = MLR 3. Used with European under-counter solution
4 = MLR 4 Use with USA cool box solution -- pipes are fl ushed with water without steam
5 = MLR 5. Used KS 6 above counter fridge -- RECOMMENDED SETTING
Config1...
Applies to software versions 2.10 and greater
0 = Grounds counter feature Enabled
1 = Milk, Bean sensor and Grounds counter enabled
2 = Nothing activated
3 = Milk sensor only
- Section 3: Page 15 -
EGRO 55 SERIES TECHNICAL MANUAL
Config2...
NOTE: ONLY the Grounds counter
Service...
USED FOR
MODEL 5513
ONLY
USED FOR
MODEL 5513
ONLY
E55_TM_programmingV3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Egro 5511Egro 5513