1.3b PRE-INSTALLATION REQUIREMENTS FOR EGRO MODEL 5513 WITH A MODEL KS FRIDGE
A
LL
(
TWO MACHINES
ELECTRICAL REQUIREMENTS
NEMA L6-30R (220 volt - 30 amp) receptacle is required.
120V standard grounded receptacle is required for the Model KS Fridge.
PLEASE NOTE: Egro coffee machines do not use a neutral line. A dedicated
ground wire is required for proper performance.
Machine requires a cold water line with a male
shut off valve (within in 4ft. of machine).
Water should be installed in accordance with local laws.
Hardness of water going to espresso machine should be tested and should be
less than 4 GPG or the warranty of the machine may be voided.
PLEASE NOTE: A water fi ltration and softening system can be purchased
through Rancilio or a high quality espresso equipment fi ltration system may
be used, however all pre-installed systems are subject to inspection and
approval by a certifi ed Rancilio technician.
Machine requires a 1 inch (inter diameter) drain pipe installed.
Connection for drain hose must be 12 inches below counter top and less than
4 feet from the intended location of the machine.
Drain must be installed in accordance with local laws.
On installation day you must have 2lbs of each types of coffee (i.e. 2lbs of
regular espresso beans & 2lbs of decaf espresso beans) you are serving.
© Copyright 2008. Rancilio North America
R
A
EQUIREMENTS
RE
=
DOUBLE COUNTER SPACE
Counter must be able to support 200lbs.
Counter space available must be 30"W x 26
39"H*.
Counter needs a 3
water, and/or drain hoses. Hole should be
located in the center of where the machine will be placed.
* These dimensions include 6" of clearance on all sides of the machine.
WATER REQUIREMENTS
DRAIN REQUIREMENTS
COFFEE REQUIREMENTS
N
F
E
ECESSARY
OR
ACH
, 2
ELECTRICAL LINES
COUNTER TOP REQUIREMENTS
1
/
inch access hole for electrical lines,
2
3
/
" NPT fi tting and a manual
8
- Section 1: Page 6 -
EGRO 55 SERIES TECHNICAL MANUAL
M
I
ACHINE
NSTALLED
, 2
, 2
WATER LINES
DRAINS ETC
1
/
"D x
2
1
(ø30mm)
2
(3/8" NPT)
...)
33"
24"
= Ground
= Hot leg
3
(3/8" BSPT)