REGISTER 8—POWER-DOWN TEST REGISTER
CR1
COUNTER_RESET
0
NORMAL
1
RESET
RR2
CDR_RESET
0
NORMAL
1
RESET
PD7
PA_ENABLE_Rx_MODE
0
PA OFF
1
PA ON
SW1
0
1
It is not necessary to write to this register under normal
operating conditions.
Rx_RESET
DB15
DB14
DB13
DB12
DB11
CR1
RR2
RR1
PD7
SW1
RR1
DEMOD_RESET
0
NORMAL
1
RESET
Tx/Rx_SWITCH_ENABLE
DEFAULT (ON)
OFF
LE1
LOG_AMP_ENABLE
0
LOG AMP OFF
1
LOG AMP ON
PD6
DEMOD_ENABLE
0
DEMOD OFF
1
DEMOD ON
Figure 70. Register 8—Power-Down Test Register Map
DB10
DB9
DB8
DB7
DB6
LE1
PD6
PD4
PD3
PD5
PD4
FILTER_ENABLE
0
FILTER OFF
1
FILTER ON
PD5
ADC_ENABLE
0
ADC OFF
1
ADC ON
For a combined LNA/PA matching network, Bit DB11 should
always be set to 0, which enables the internal Tx/Rx switch. This
is the power-up default condition.
Rev. 0 | Page 53 of 60
CONTROL
BITS
DB5
DB4
DB3
DB2
DB1
RES
PD1
C4 (1)
C3 (0)
C2 (0) C1 (0)
PD1
SYNTH_ENABLE
0
SYNTH OFF
1
SYNTH ON
PD3
LNA/MIXER_ENABLE
0
LNA/MIXER OFF
1
LNA/MIXER ON
ADF7021-V
DB0
Need help?